Type |
ZLF-35N ZLF-35NS ZLF-35NH ZLF-35NSH |
ZLF-50N ZLF-50NS ZLF-50NH ZLF-50NSH |
ZLF-80N ZLF-80NS ZLF-80NH ZLF-80NSH |
ZLF-125N ZLF-125NS ZLF-125NH ZLF-125NSH |
ZLF-200N ZLF-200NS ZLF-200NH ZLF-200NSH |
Medium temp. range |
-45~ 250degree (setting the max temp according to the supplier heating or cooling source) -40~135degree(The maximum temperature range can be operated by using glycol water formula.) |
||||
ZLF- N |
The main cold source/or main heat source is used to regulate the flow of the system through proportional regulation system, and control the heat of the clamping of the reaction tank, and a set of heat exchanger for heating or cooling is controlled or cooled. |
||||
ZLF- NS |
Besides ZLF- N function,add one set heater used to reduce high temp. |
||||
ZLF- NH |
Besides ZLF- N function,add electrical heating function |
||||
ZLF- NSH |
Besides ZLF- N function,add one set heater used to reduce high temp and electrical heating function |
||||
Heat exchanger area |
3.5m2 |
5m2 |
8m2 |
12.5m2 |
20m2 |
Electric heating function H |
25KW |
35KW |
50KW |
65KW |
80KW |
With “H” has heating function |
|||||
Control mode |
PID adaptive controller,special dynamic control calculation, Lneya controller |
||||
communication |
MODBUS RTU protocol RS485 interface,optional ethernet interface/R232 interface |
||||
Temperature control selection |
Material control temp. |
||||
Temperature feedback |
The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor |
||||
Material temperature feedback |
Material temp. feedback:PT100 or 4~20mA or communication given Temp.feedback:PT100 |
||||
Material temperature accuracy |
±1℃ |
±1℃ |
±1℃ |
±2℃ |
±2℃ |
Circulating pump |
150L/min 2.5BAR |
200L/min 2.5BAR |
400L/min 2.5BAR |
500L/min 2.5BAR |
750L/min 2.5BAR |
Input, display |
7-inch color touch screen display and touch key input, temp curve display |
||||
Security and protection |
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
||||
Perform valve piece |
Electric proportional control valve, control signal 4~20mA. |
||||
Piping material |
SUS304 |
||||
The interface size |
DN40 |
DN40 |
DN-50 |
DN-65 |
DN-80 |
Installation dimensions |
1000*950*1750 |
1250*1000*2000 |
1500*1250*2050 |
2050*1450*2050 |
2050*1450*2050 |
External dimension EX |
1000*1200*1750 |
1250*1250*2000 |
1500*1500*2050 |
2050*1450*2050 |
2050*1450*2050 |
The power supply |
AC380V 50HZ 1.6kw(max) |
AC380V50HZ 2.1kw(max) |
AC380V50HZ 2.5kw(max) |
AC380V50HZ 5.7kw(max) |
AC380V50HZ 7.7kw(max) |
Suffix H power supply |
AC380V 50HZ 26.6kw(max) |
AC380V50HZ 37.1kw(max) |
AC380V50HZ 52.5kw(max) |
AC380V50HZ 70.7kw(max) |
AC380V50HZ 87.7kw(max) |
Shell material |
SUS 304 |
SUS 304 |
SUS 304 |
SUS 304 |
SUS304 |
سوف نتصل بك في غضون 24 ساعة.