Type |
SR-35N SR-35NS SR-35NH SR-35NSH |
SR-50N SR-50NS SR-50NH SR-50NSH |
SR-80N SR-80NS SR-80NH SR-80NSH |
SR-125N SR-125NS SR-125NH SR-125NSH |
SR-200N SR-200NS SR-200NH SR-200NSH |
Medium temp. range |
-120~ 250degree setting the max temp according to the supplier heating or cooling source) -40~135degree(The maximum temperature range can be operated by using glycol water formula.) |
||||
SR- N |
A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank. |
||||
SR- NS |
Besides SR- N function,add one set heater used to reduce high temp. |
||||
SR- NH |
Besides SR- N function,add electrical heating function |
||||
SR- NSH |
Besides SR- N function,add one set heater used to reduce high temp and electrical heating function |
||||
Tank capacity |
100L |
200L |
280L |
390L |
500L |
Heat exchanger area |
3.5m2 |
5m2 |
8m2 |
12.5m2 |
20m2 |
Electric heating function H |
25KW |
35KW |
50KW |
65KW |
80KW |
With“H” has heating function |
|||||
|
PID adaptive controller,special dynamic control calculation, Lneya controller |
||||
communication |
MODBUS RTU protocol RS485 interface,optional ethernet interface/R232 interface |
||||
Temperature control selection |
Material control temp. |
||||
Temperature feedback |
The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor |
||||
Material temperature feedback |
Material temp. feedback:PT100 or 4~20mA or communication given Temp.feedback:PT100 |
||||
Material temperature accuracy |
±1℃ |
±1℃ |
±1℃ |
±2℃ |
±2℃ |
Circulating pump |
200L/min 2.5BAR |
250L/min 2.5BAR |
400L/min 2.5BAR |
500L/min 2.5BAR |
750L/min 2.5BAR |
Input, display |
7-inch color touch screen display and touch key input, temp curve display |
||||
Security and protection |
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
||||
Perform valve |
Electric proportional control valve, control signal 4~20mA. |
||||
Piping material |
SUS304 |
||||
The interface size |
DN40 |
DN40 |
DN-50 |
DN-65 |
DN-80 |
Installation dimensions |
1000*1200*1750 |
1250*1250*2000 |
1500*1500*2050 |
2050*1450*2050 |
2050*1450*2050 |
POWER |
AC380V 50HZ 1.6kw(max) |
AC380V50HZ 2.1kw(max) |
AC380V50HZ 2.5kw(max) |
AC380V50HZ 5.7kw(max) |
AC380V50HZ 7.7kw(max) |
Suffix H power supply |
AC380V 50HZ 26.6kw(max) |
AC380V50HZ 37.1kw(max) |
AC380V50HZ 52.5kw(max) |
AC380V50HZ 70.7kw(max) |
AC380V50HZ 87.7kw(max) |
Shell material |
SUS 304 |
SUS 304 |
SUS 304 |
SUS 304 |
SUS304 |
سوف نتصل بك في غضون 24 ساعة.