Model | LC-12W | LC-20W | LC-30W | LC-40W | LC-60W | LC-80W | LC-120W | LC-180W | LC-240W | LC-360W |
Temperature Range ℃ |
-25°C~ 5°C | |||||||||
Cooling Capacity | 12kW | 20kW | 30kW | 40kW | 60kW | 80kW | 120kW | 180kW | 240kW | 360kW |
At -20°C(Kcal/h) | 10320 | 17200 | 25800 | 34400 | 51600 | 68800 | 103200 | 154800 | 206400 | 309600 |
Circulation Pump | 6.6m³/h | 9m³/h | 15m³/h | 15m³/h | 25m³/h | 25m³/h | 25m³/h | 35m³/h | 35m³/h | 50m³/h |
2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | 2.5bar | |
Inlet&outlet | DN-25 | DN-25 | DN-32 | DN-32 | DN-40 | DN-40 | DN-40 | DN-50 | DN-50 | DN-65 |
connection size | PN-10 | PN-10 | PN-10 | PN-10 | PN-10 | PN-10 | PN-10 | PN-10 | PN-10 | PN-10 |
Water-cooled | 8m³/h | 10m³/h | 16m³/h | 20m³/h | 25m³/h | 30m³/h | 38m³/h | 55m³/h | 70m³/h | 100m³/h |
(cooling at 30℃) | ||||||||||
Cold storage tank | 200L | 350L | 500L | 750L | 1000L | 1200L | 1500L | 2200L | 3000L | 4000L |
(optional) | ||||||||||
Expansion tank | 100L | 175L | 250L | 350L | 500L | 600L | 750L | 1000L | 1350L | 1800L |
(standard) | ||||||||||
Intermediate heat | KAORI Plate heat exchanger | |||||||||
exchanger | ||||||||||
Reservoir | Standard:RSP | |||||||||
Optional:Emerson | ||||||||||
Sight glass | Standard: SANHUA Optional: Danfoss | |||||||||
Refrigeration | Standard: SANHUA Optional: Danfoss | |||||||||
ball valve | ||||||||||
Electric | Schneider AC contactor, Schneider intermediate relay | |||||||||
Refrigerant | R404A | |||||||||
Secondary | No corrosive liquid, ethanol water, ethylene glycol aqueous solution, heat transfer oil etc. | |||||||||
refrigerant | ||||||||||
Safety protection | High pressure protect; Water supply cut-off protection; Over-current protection; Leakage protection; | |||||||||
Sequential and phase failure protection; High temperature protection; Sensor Failure protection; | ||||||||||
Sequential and phase failure protection; High temperature protection; | ||||||||||
Liquid low level protection etc. muti-safety protection. | ||||||||||
Sensor Failure protection; Liquid low level protection etc. muti-safety protection. | ||||||||||
Level Indicator | Adpot glass liquid level indication | |||||||||
Piping material | SUS304 | |||||||||
Expansion tank | SUS304 | |||||||||
material | ||||||||||
Case material | Steel channel + Square tube + Cold-rolled blanking plate painting | |||||||||
Product size(cm) |
160*100 *165 |
160*100 *165 |
180*120 *175 |
180*120 *175 |
205*145 *175 |
235*145 *175 |
245*145 *205 |
350*150 *205 |
350*150 *205 |
450*200 *205 |
Power 380V 50HZ(max) |
10kW | 14kW | 22kW | 31kW | 45kW | 61kW | 86kW | 127kW | 167kW | 247kW |
HP | 12HP | 15HP | 25HP | 35HP | 50HP | 70HP | 100HP | 150HP | 200HP | 300HP |
dB | 75DB | Within80dB | Within90dB | |||||||
Weight | 800kg | 950kg | 1200kg | 1350kg | 1500kg | 1800kg | 2400kg | 3100kg | 3600kg | 5000kg |
Compressor | Standard:Copeland | ||||
Optional:BOCK piston compressor | |||||
Operation Panel | 7-inch color touch screen display, temperature curve record, data export to excel format. | ||||
Control System | Standard: Single-chip microcomputer controller; Stepping control; Set temperature difference of refrigeration on & off. | ||||
Optional: SIEMENS S7-200PLC&Module | |||||
Closed | The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, | ||||
circulation system | pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||
Circulation pump | Standard:Direct type magnetic pump | ||||
Optional: Increase the pipeline magnetic pump pressure in the pipeline | |||||
Evaporator | Standard: Braze welding plate heat exchager (BPHE) | ||||
Optional: Stainless steel tube heat exchanger | |||||
Condenser | Shell and tube type water cooled condenser |