Model |
DQY-6075S |
DQY-8075S |
DQY-A075S |
|
Chamber temp. range |
-75℃~180℃ |
-75℃~180℃ |
-75℃~180℃ |
|
Object temp. range |
-60℃~160℃ |
-60℃~160℃ |
-60℃~160℃ |
|
Chamber volume |
Φ0.6×1m |
Φ0.8×1m |
Φ1×1.3m |
|
Heating power |
5kw |
7.5kw |
10kw |
|
Temp. constancy |
±0.5℃(Normal pressure, no load.) |
|||
Temp. uniformity |
±2℃(Normal pressure, no load.) |
|||
Temp deviation |
±3℃(Normal pressure, no load.) |
|||
Object Temp. Control |
Depression can choose + / - 1 ℃ accuracy of temperature control on the surface of theobject Temp. Accuracy:±1℃ |
|||
Heating rate |
1.5~2.5℃/min |
|||
Cooling rate |
1~2.5℃/min |
|||
Pressure range |
Normal pressure~0.1kPa |
|||
Pressure deviation |
Atmospheric pressure~40Kp:±1.8Kpa;40Kp~4Kpa:±4.5%;4Kp~0.1KPa:±0.1Kpa |
|||
Decompression time |
≤45min(Atmospheric pressure~0.5kPa) |
|||
Controller |
Siemens PLC controller, Siemens color LCD touch screen. |
|||
Precision range |
Setting accuracy: 0.01K, indicating accuracy: 0.01K. |
|||
Temperature sensor |
Platinum resistance PT100Ω/MV |
|||
Pressure sensor |
Electronic pressure transmitter. |
|||
Heater |
Fully independent system, stainless steel flange pipe heater. |
|||
Internal evaporator |
Copper tube aluminum fins. |
|||
Plate heat sink |
Aluminium |
|||
Circulation pump |
Guanya Magnetic circulation pump |
|||
Secondary refrigerant |
KDOC-80 Thermal conductive silicone oil |
|||
Compressor |
Tecumseh |
Dorin |
Dorin |
|
Condenser |
Paris/shen's Tube heat exchanger. |
|||
Cooling type |
Water-cooled |
|||
Cooling water 25 degrees |
1500L/h 2bar |
2200L/h 2bar |
3000L/h 2bar |
|
Circulation system |
High temperature and low noise air conditioning motor. Multi-blade centrifugal wind turbine |
|||
Chamber material |
High quality carbon steel plate. Phosphating electrostatic spraying process /SUS304 stainless steel fog face line texturing treatment. |
|||
Inner Material |
SUS304 |
|||
Heat preservation material |
Polyurethane rigid foaming/ultra fine glass fiber cotton. |
|||
Door frame and heat insulation |
Double layer high and low temperature aging silicone rubber door sealing strip. |
|||
Security and protection |
Leakage, short circuit, over-temperature, motor overheat, overload, over-current protection have self-diagnosis function;Overload protection of freezer;High pressure pressure switch, cooling water lack of protection and other security functions. |
|||
Power 380V 50HZ |
12KW MAX |
16kw MAX |
23KW MAX |
يلبي الطلب:
Gb10590-89 ظروف درجة حرارة منخفضة / اختبار الضغط المنخفض الغرفة الفنية ؛
Gb15091-89 ظروف درجة حرارة عالية / الضغط المنخفض غرفة الاختبار الفنية ؛
GB11159-89 الشروط الفنية مربع اختبار الضغط المنخفض ؛
GB / T2423.25-1992 غرفة اختبار درجة حرارة منخفضة / منخفضة الضغط الشامل ؛
GB / T2423.26-1992 غرفة اختبار درجة حرارة عالية / منخفضة الضغط الشامل ؛
GJB150.2-86 غرفة درجة الحرارة المنخفضة / الضغط المنخفض (الارتفاع) ؛
سوف نتصل بك في غضون 24 ساعة.